Atelier ValeDATA CENTER EQUIPMENT
Atelier Vale LLC · Equipment collection

Room for
what comes next.

Explore a 52U server rack concept and configurable PDU families, transfer switches and distribution cabinets for your project.

Prepare an enquiry ↗Explore specifications

Preliminary design · Pricing and availability to be confirmed

Smart power for AI data centers: high density, smart monitoring and custom solutions
AI-generated promotional illustration
52UEquipment capacity
750 mmExternal width
1200 mmExternal depth
Solution design: server rack and structured blue cabling

AI-generated promotional illustration · Solution design

New / Power equipment collection

Explore the PDU & power range.

Explore the RP5306F 208V three-phase metered PDU, six configurable PDU families, transfer switches and distribution cabinets.

Explore products ↗ RP5306F PDU specifications ↗
01 / Cabinet

A clear starting point.
A configurable interior.

The reference establishes capacity, width and depth. The proposed cabinet adds adjustable mounting rails, removable panels and rear cable-management space.

Proposed model · AV-52U-7512
Concept rendering of a black server rack, showing front and rear views with optional dual vertical PDUs
CONCEPT RENDERING — illustrative equipment and PDU layout.
The model identifier is a proposed catalogue reference. Final dimensions, load ratings and included accessories require manufacturer confirmation.
Capacity / exterior footprint52U / 750 W × 1200 D mm
Reference requirements
Overall heightApprox. 2450 mm · provisional
Mounting systemProposed 19-inch, four adjustable rails
DoorsProposed perforated front door and split rear doors
Side accessProposed removable, lockable panels
Cable routingProposed top brush entries and rear vertical channels
FinishProposed black powder-coated steel
Load rating / usable depthPending manufacturer verification
02 / Power planning

Power, specified
for the project.

Reference PDU requirements below. Cabinet-only and bundled configurations must be confirmed in the final quotation.

01 — INPUT

208V · 3-phase · 50A

CS8365C male input plug. Site supply and mating receptacle compatibility must be verified.

02 — DISTRIBUTION

Metered, vertical 0U

IEC C13 / C19 outlets. Outlet counts, PDU dimensions and metering features remain to be specified.

03 — CAPACITY

Up to 14.4 kW*

As stated in the reference. Rating conditions and usable capacity require confirmation. Optional dual-PDU provision does not establish redundant usable capacity.

No UL/ETL certification claim is made for this preliminary concept. Applicable documentation must be verified for the exact supplied products.

03 / Define your configuration

Start with
your requirements.

Prepare a project brief for cabinet quantity, power options and delivery requirements.

Create your enquiry below, then open it in your email app and send it to our sales contact. Your enquiry is only sent when you press Send in your email app.

Sales enquiries
sales@ateliervaletech.com

Before ordering: confirm manufacturing drawings, load rating, actual product photographs, price, lead time, freight terms and warranty.